M-ZP sBox
Purpose
The M-ZP sBox is used to increase the number of zones and outputs in the system with the possibility of moving them away from the control panel at a distance of up to 1000 m.
This will be useful for connecting security detectors and automation in remote parts of the facility - another floor, another building, etc.
This way, you can reduce the number of wires and optimise the system topology.
This will be useful for connecting security detectors and automation in remote parts of the facility - another floor, another building, etc.
This way, you can reduce the number of wires and optimise the system topology.

Designed by professionals

8 basic signalling zones
Universal slot for mounting the M-OUT2R relay module
Touch Memory interface
Tamper protection against opening the housing and detachment from the installation surface
Power and signal transistor outputs
8 basic signalling zones
Universal slot for mounting the M-OUT2R relay module
Touch Memory interface
Tamper protection against opening the housing and detachment from the installation surface
Power and signal transistor outputs
Features
8 signalling zones
2 transistor outputs
Interface for connecting TM readers
Possibility to install the M-OUT2R module
Built-in power supply 15 W
Protection against opening of the housing and detachment from the installation site
Connection via RS-485 system bus with a line length of up to 1000 m
Technical parameters
Compatibility
Orion NOVA L/L(i)
Orion NOVA M/M(i)
Connection to the SCP
RS-485 system bus with cryptographic exchange
Twisted pair cable category 5 or higher
Communication line length with up to 1000 m
Zones
8 wired zones in the base
Outputs.
Transistor signal output
Transistor power output
Power supply
Main power supply:
220 V, 50 Hz
220 V, 50 Hz
Backup power supply:
Lead-acid battery
for 2.2 Ah
Lead-acid battery
for 2.2 Ah
Maximum total output current:
500 mA
500 mA
Built-in 15 W power supply unit
Case
Overall dimensions:
280x280x80 mm
280x280x80 mm
Weight:
800 g
800 g
Degree of protection of the enclosure:
IP30
IP30
Operating temperature range:
-10°C to +40°C
-10°C to +40°C